integrated-pipeline-mode

IIS7 ISAPI Filter Module & HttpModule Events - How do they line up?

放肆的年华 提交于 2019-12-01 07:03:33
So IIS7 in Integrated Pipeline mode uses a IsapiFilterModule to shim ISAPI filter DLL's and fire off the correct "events" on the filters, which is quite different than previous versions of IIS or IIS7 in classic mode because this means that HttpModules fire off right along side ISAPI filters in Integrated Pipeline mode. So does anyone happen to know how ISAPI events ( http://msdn.microsoft.com/en-us/library/ms524855.aspx ) and the HttpModule events ( http://msdn.microsoft.com/en-us/library/ms998536.aspx ) line up? VMAtm HttpModule events are fired after other filters, according to the MSDN: At

HttpModule.Init - safely add HttpApplication.BeginRequest handler in IIS7 integrated mode

限于喜欢 提交于 2019-11-29 17:36:16
问题 My question is similar but not identical to: Why can't my host (softsyshosting.com) support BeginRequest and EndRequest event handlers? (I've also read the mvolo blog referenced therein) The goal is to successfully hook HttpApplication.BeginRequest in the IHttpModule.Init event (or anywhere internal to the module), using a normal HttpModule integrated via the system.webServer config, i.e. one that doesn't: invade Global.asax or override the HttpApplication (the module is intended to be self

sitecore template standard values layout not updating all items, layout not loading

筅森魡賤 提交于 2019-11-29 13:04:34
i'm currently having a nightmarish moment with Sitecore. Basically my issues are two-fold: 1) the first time i added a standard value item to a template, and added a layout setup to it, i was thrilled, since all my items from that template were showing the layout, however now, certain items are now showing no layout at all. I tried doing presentation->layout, reset several times, but to no avail. 2) i added a new sublayout to the standard value layout to another placeholder, did publish on the template (republish everything, publish subitems), then publish on the standard values item again,

sitecore template standard values layout not updating all items, layout not loading

耗尽温柔 提交于 2019-11-28 06:13:13
问题 i'm currently having a nightmarish moment with Sitecore. Basically my issues are two-fold: 1) the first time i added a standard value item to a template, and added a layout setup to it, i was thrilled, since all my items from that template were showing the layout, however now, certain items are now showing no layout at all. I tried doing presentation->layout, reset several times, but to no avail. 2) i added a new sublayout to the standard value layout to another placeholder, did publish on

Impersonate Domain User with Integrated Pipeline

时光总嘲笑我的痴心妄想 提交于 2019-11-27 17:32:30
This is a question that continues to haunt me... In an local Intranet environment, are we doomed to use "Classic" pipeline mode in our App Pool if we want to use Impersonate our Windows domain users, or is there a new way to declaratively "run as" them (so-to-speak)? My goal is to use Windows Authentication for local web applications on my Intranet so users can authenticate and run apps under their active directory account (principle). Every time I try this (Using the NetworkService identity of course), I get this error: Thanks! ;) I wrote a small app to display the current user's network

Impersonate Domain User with Integrated Pipeline

浪尽此生 提交于 2019-11-26 22:34:36
问题 In an local Intranet environment, are we doomed to use "Classic" pipeline mode in our App Pool if we want to use Impersonate our Windows domain users, or is there a new way to declaratively "run as" them (so-to-speak)? My goal is to use Windows Authentication for local web applications on my Intranet so users can authenticate and run apps under their active directory account (principle). Every time I try this (Using the NetworkService identity of course), I get this error: 回答1: I wrote a

“This operation requires IIS integrated pipeline mode.”

旧时模样 提交于 2019-11-26 13:22:58
问题 I have a web application being developed on Windows 8.1, .NET 4.5.1, IIS 8.5 (under Integrated AppPool), Visual Studio 2013 over the default template that includes ASP.NET Identity, Owin, etc. and locally it works fine. Then I uploaded it to a Windows Server 2008 using IIS 7.5 (Integrated Pipeline) Host and I get: This operation requires IIS integrated pipeline mode. Exception Details: System.PlatformNotSupportedException: This operation requires IIS integrated pipeline mode. Stack Trace:

What is the difference between 'classic' and 'integrated' pipeline mode in IIS7?

别等时光非礼了梦想. 提交于 2019-11-26 00:26:50
问题 I was deploying an ASP.NET MVC application last night, and found out that it is less work to deploy with IIS7 set to integrated mode. My question is what is the difference? And what are the implications of using one or the other? 回答1: Classic mode (the only mode in IIS6 and below) is a mode where IIS only works with ISAPI extensions and ISAPI filters directly. In fact, in this mode, ASP.NET is just an ISAPI extension (aspnet_isapi.dll) and an ISAPI filter (aspnet_filter.dll). IIS just treats