What is a good way to show a floating point number via SNMP?

后端 未结 3 1037
栀梦
栀梦 2021-01-05 05:26

I am coding an SNMP Agent. I need to send values that have a decimal point to an SNMP Manager.

I have a couple options:

  1. Truncate the number.
相关标签:
3条回答
  • 2021-01-05 05:51

    The usual, standard way this is done is to define a TEXTUAL-CONVENTION with an integral type (such as Integer32 or Unsigned32) and a DISPLAY-HINT with "d-N" format, where N is the number of places the decimal should be shifted for display purposes.

    Thus, for a value with a single decimal place ranging from (say) 0.0 to 10.0, you would use a TEXTUAL-CONVENTION of type Unsigned32(0..100) and a DISPLAY-HINT of "d-1". On the wire, the value ranges from 0 to 100, but the manager (by way of the MIB module being loaded) will shift the decimal one place to display a range of 0.0 to 10.0.

    Other ways of doing it are not conducive to interoperability.

    0 讨论(0)
  • 2021-01-05 06:01

    as an octect-stream in IEEE-754 format (8 Octets). See: http://en.wikipedia.org/wiki/IEEE_754-2008

    0 讨论(0)
  • 2021-01-05 06:05

    I rather send that data via OCTET STRING/DisplayString. Numbers such as "1.5" can be sent easily.

    However, if the data need to be accurate, you may use Kyle's suggestion by sending bytes (octets). Noticeably that is also sent via OCTET STRING as it is a perfect byte container.

    0 讨论(0)
提交回复
热议问题