I am coding an SNMP Agent. I need to send values that have a decimal point to an SNMP Manager.
I have a couple options:
The usual, standard way this is done is to define a TEXTUAL-CONVENTION with an integral type (such as Integer32 or Unsigned32) and a DISPLAY-HINT with "d-N" format, where N is the number of places the decimal should be shifted for display purposes.
Thus, for a value with a single decimal place ranging from (say) 0.0 to 10.0, you would use a TEXTUAL-CONVENTION of type Unsigned32(0..100) and a DISPLAY-HINT of "d-1". On the wire, the value ranges from 0 to 100, but the manager (by way of the MIB module being loaded) will shift the decimal one place to display a range of 0.0 to 10.0.
Other ways of doing it are not conducive to interoperability.
as an octect-stream in IEEE-754 format (8 Octets). See: http://en.wikipedia.org/wiki/IEEE_754-2008
I rather send that data via OCTET STRING/DisplayString. Numbers such as "1.5" can be sent easily.