setting parity with controlTransfer method

前端 未结 1 902
夕颜
夕颜 2020-12-29 14:37

Anybody knows how to set the parity with the controlTransfer in Android?

I can\'t find the explanation of this method\'s parameters anywhere - just some generic i

相关标签:
1条回答
  • 2020-12-29 15:27

    You can define the combination of bits to create your own configuration (parity, stop bit & data bit).

    conn.controlTransfer(0x40, 0x04, 0x0008, 0, null, 0, 0); 
    

    1st parameter - 0x40  - request to set or get control data

     #define FTDI_SIO_SET_DATA_REQUEST_TYPE  0x40
    

    2nd parameter - 0x04 - type of data to be set or get

    #define FTDI_SIO_RESET      0 /* Reset the port */
    #define FTDI_SIO_MODEM_CTRL     1 /* Set the modem control register */
    #define FTDI_SIO_SET_FLOW_CTRL  2 /* Set flow control register */
    #define FTDI_SIO_SET_BAUD_RATE  3 /* Set baud rate */
    #define FTDI_SIO_SET_DATA   4 /* Set the data characteristics of the port */
    #define FTDI_SIO_GET_MODEM_STATUS   5 /* Retrieve current value of modern status register */
    #define FTDI_SIO_SET_EVENT_CHAR 6 /* Set the event character */
    #define FTDI_SIO_SET_ERROR_CHAR 7 /* Set the error character */
    

    Third parameter - 0x0008 - data bit 8, parity none, stop bit 1, tx off - Is the actual data to be passed.

    The third parameter is a 16 bit data which can be formed from the constants defined below:

    Bits 0 to 7   -- Number of data bits
    
    Bits 8 to 10  -- Parity
              0 = None
              1 = Odd
              2 = Even
              3 = Mark
              4 = Space
    Bits 11 to 13 -- Stop Bits
              0 = 1
              1 = 1.5
              2 = 2
    Bit 14
              1 = TX ON (break)
              0 = TX OFF (normal state)
    Bit15 -- Reserved
    
    
     #define FTDI_SIO_SET_DATA_REQUEST       FTDI_SIO_SET_DATA
    
     #define FTDI_SIO_SET_DATA_PARITY_NONE   (0x0 << 8)
     #define FTDI_SIO_SET_DATA_PARITY_ODD    (0x1 << 8)
     #define FTDI_SIO_SET_DATA_PARITY_EVEN   (0x2 << 8)
     #define FTDI_SIO_SET_DATA_PARITY_MARK   (0x3 << 8)
     #define FTDI_SIO_SET_DATA_PARITY_SPACE  (0x4 << 8)
     #define FTDI_SIO_SET_DATA_STOP_BITS_1   (0x0 << 11)
     #define FTDI_SIO_SET_DATA_STOP_BITS_15  (0x1 << 11)
     #define FTDI_SIO_SET_DATA_STOP_BITS_2   (0x2 << 11)
     #define FTDI_SIO_SET_BREAK              (0x1 << 14)
    

    For baud rate :

    * Value Baud Rate speed
    * 0×2710 300
    * 0×1388 600
    * 0x09C4 1200
    * 0x04E2 2400
    * 0×0271 4800
    * 0×4138 9600
    * 0x80D0 14400
    * 0x809C 19200
    * 0xC04E 38400
    * 0×0034 57600
    * 0x001A 115200
    * 0x000D 230400
    * 0×4006 460800
    * 0×8003 921600
    */
    

    Please refer the below links for more details:

    http://read.pudn.com/downloads181/sourcecode/embed/842049/usb/serial/ftdi_sio.h__.htm

    http://www.mev.co.uk/pages/Support/USB-Baud-Spoof.html