No Runtime can be found in Worklight Console

后端 未结 1 1858
猫巷女王i
猫巷女王i 2020-12-20 02:20

I am trying to set up test environemnt for worklight project. Every thing looks like started successfully without any errors , however, the worklight console says \'No runti

相关标签:
1条回答
  • 2020-12-20 02:50

    The problem you are seeing is due to an issue in Liberty Profile 8.5.5.2. The issue is tracked as APAR PI17830. The fix for this issue is currently planned for Liberty Profile 8.5.5.3, but that is not yet available.

    In the interim, please downgrade to Liberty Profile 8.5.5.1, and also ensure that you are using the August 1st (or later) build of Worklight Studio.

    0 讨论(0)
提交回复
热议问题