WCF - The maximum nametable character count quota (16384) has been exceeded while reading XML data

前端 未结 4 1214

I\'m having a WCF Service that uses wsHttpBinding. The server configuration is as follows :


      &l         


        
4条回答
  •  时光说笑
    2020-12-17 22:09

    One thing to recognize is that the message refers to the svcutil reader quotas not the service ones! Svcutil has a limit on how much metadata it can read. This limit can be changed with a config file. The solution is to create a config file for svcutil and place it in the same folder as the tool. Next time you run svcutil, the config file values will be taken into account.

    http://geekswithblogs.net/claraoscura/archive/2007/08/20/114806.aspx